Crankweb deflection measurement is the simple, low-cost check that catches the problem early. This guide explains when to take readings, how to take them correctly, how to read the results and what corrective work they usually lead to on African mine and utility stations.
What deflection tells you
Deflection is the change in distance between two crank webs as the shaft is turned through a full revolution. If the main bearings either side of a crank throw are perfectly aligned, the distance barely changes. If one bearing sits lower than its neighbours, the webs open and close as the shaft turns, and a dial gauge between them shows the movement.
The readings therefore give an indirect picture of main bearing alignment, bearing wear, foundation and chock condition, and the alignment between the engine and the alternator. They do not replace bearing inspections, but they tell the service team where to look.
When to take readings
Follow the maker’s interval, which is often tied to running hours and to each scheduled maintenance stop. Readings are also essential after main bearing replacement, after any work on the engine foundation or chocks, after the alternator has been moved or realigned, and after an abnormal event such as a high bearing temperature alarm, an oil mist detector trip or a severe short circuit on the generator.
On a new or relocated engine, take a full set at commissioning. That baseline is the reference against which every later set is compared, and without it trend analysis is much harder. Our article on what to expect from an HFO overhaul shows where these readings fit into the wider overhaul record.
Gauges and mounting
The standard tool is a crankweb deflection indicator: a dial or digital gauge on an extension that fits between the webs. Most crankshafts have punch marks on the webs showing where the gauge must sit, set at a fixed distance from the crankpin centre. Using the marks matters, because readings taken at a different radius are not comparable with earlier sets.
Check the gauge before use, make sure it sits firmly without being forced, and zero it in the first position. Digital gauges that log readings automatically reduce transcription errors, which are a common source of false alarms.
The measuring procedure
With the engine stopped, isolated and locked out, open the crankcase doors and turn the engine with the turning gear in its normal running direction. Take readings at defined positions around the revolution, commonly near bottom dead centre on one side, then at the side, top and opposite side positions, and finally near bottom dead centre on the other side. The two bottom readings are taken either side of the connecting rod, because the rod prevents a reading at the exact bottom.
Record the position of each reading, the oil and jacket water temperatures, and whether the engine is cold or warm. Many makers specify readings within a set time after stopping, or at a stated temperature, because the shaft and the engine block grow as they heat.
Reading the results
The vertical deflection is the difference between the top reading and the average of the two bottom readings. The horizontal deflection is the difference between the two side readings. Sign conventions vary between makers, so always use the convention in the engine manual; a positive value on one engine type can mean the opposite on another.
As an example, if the top reading is zero and the two bottom readings average minus 0.06 millimetres, the vertical deflection is 0.06 millimetres in the direction the manual defines. Whether that is acceptable depends on the maker’s limit, often stated as a value related to the stroke, with separate figures for new installations, normal service and immediate correction.
Patterns along the crankshaft
Single values matter less than the pattern from throw to throw. A large deflection on one throw with small values either side points to a single low or worn bearing. A gradual change along the shaft suggests foundation settlement or bending of the engine frame. A high value on the throw nearest the flywheel, especially when it changes after alternator work, often points to coupling alignment or alternator bearing wear.
Comparing each new set with the baseline and the last two sets is the most useful view. A value within limits that is changing quickly deserves more attention than a steady value close to the limit.
Causes seen on African stations
Field teams on mine and utility stations across the region find a repeating list of causes: cracked or poorly cured concrete foundations, loose holding-down bolts, fretting or crushed chocks, resin chocks that were poured without proper surface preparation, soft ground under containerised sets, and alternators moved during transport without full realignment afterwards.
High engine hall temperatures and engines that start and stop often add thermal movement to the mix. Where these conditions exist, shorten the measurement interval until the trend shows the shaft is stable.
Corrective work
Depending on the pattern, corrective work can include replacing worn main bearing shells, measuring and correcting bearing pocket alignment, re-tightening or replacing holding-down bolts, re-chocking with new steel or resin chocks, repairing the foundation, and realigning the alternator with laser equipment. After any of these, take a full new set of deflection readings to confirm the result.
Larger corrections often come with a crankshaft inspection for cracks and pin wear. Our engine refurbishment services cover bearing, alignment and foundation work as part of planned overhauls.
Recording and trending
Keep every set in the maintenance system with the date, running hours, temperatures, gauge used and name of the person who took it. A simple chart per throw, with the maker’s limits drawn on it, makes trends obvious to station managers who are not engine specialists.
Deflection readings take an experienced fitter a few hours. Compared with the cost and downtime of a crankshaft failure on a remote site, they are among the most valuable hours in the maintenance plan.
Who wrote this guide
This guide comes from the USP&E engine fitters and service supervisors who keep HFO generating sets aligned and running at African power stations. USP&E is an EPC and O&M contractor, not a broker, with 150+ power projects in 45+ countries, 25,000 MW contracted since 2002 and 24+ years in the field. Alignment checks are part of the routines described in our HFO station delivery and O&M guide.
Offices: Colorado Springs (1755 Telstar Dr, Suite 300), Knoxville (800 S Gay St, Suite 700), London (162-168 Regent Street), Johannesburg (22 Kildoon Rd, Bryanston), Cape Town (31 Brickfield Road, Woodstock) and China (No. 1 Ningzhou Road, Wuxi). Regions: USA | AFRICA | UK | UAE | CHINA. ISO 9001 and ISO 45001 certified.
Crankshaft deflection questions
What is crankshaft deflection?
It is the change in distance between two crank webs as the shaft turns through a revolution. It indicates how well the main bearings either side of the throw are aligned.
How often should crankshaft deflection be measured?
At the engine maker’s interval, plus after bearing, foundation, chock or alternator work and after abnormal events such as bearing temperature alarms.
Why are two bottom readings taken?
The connecting rod blocks a reading at the exact bottom position, so readings are taken on each side of the rod and averaged.
Does engine temperature affect deflection readings?
Yes. The shaft and block grow as they heat, so record temperatures and follow the maker’s instructions on hot or cold readings.
What causes high deflection on the last throw?
Often alternator coupling misalignment or alternator bearing wear, especially if the value changes after the alternator has been moved or serviced.
What happens if deflection is ignored?
Repeated bending can crack the crankshaft or destroy main bearings, causing long downtime and a costly repair.
Book an alignment check
Send us the engine models, running hours and your last deflection records, and our service engineers will plan a measurement and correction visit for your station.
Use the engine service enquiry form for a structured request, email info@uspeglobal.com with any site data you hold, or ring +27 10 822 2324 to speak to an engineer. Replacement HFO engines and generating sets are listed in our current stock list.