Cooling Water Treatment for HFO Engines at African Power Stations

When a cylinder liner pits through from the water side, or a cylinder head cracks near a cooling passage, the cause is often found in a water sample rather than in the engine. Medium-speed HFO engines run their jacket and charge air circuits as closed systems, and a closed system with the wrong water or the wrong inhibitor level corrodes, scales and cavitates steadily until a component fails.

On African stations the problem is made harder by hard or variable make-up water, long supply chains for chemicals and high ambient temperatures. This guide sets out the service routine that keeps cooling water in condition: what to fill with, what to dose, what to test and how often, and what the test results are telling the service team.

Why closed circuits still corrode

A closed cooling circuit loses very little water, so it is tempting to assume that once filled it can be left alone. In practice small leaks, venting and maintenance draining mean that fresh water enters the system regularly, bringing oxygen and dissolved salts with it. Oxygen drives corrosion of steel and cast iron, and the salts form scale on the hottest surfaces.

A second mechanism is cavitation on the outside of wet liners. Liner vibration creates tiny vapour bubbles in the water that collapse against the metal and remove it. A correct inhibitor film reduces this attack, which is why inhibitor level matters even on an engine whose water looks clean.

Starting with the right make-up water

Engine makers specify the quality of the water used to fill and top up the circuit, normally with limits on hardness, chlorides, sulphates and pH. Borehole and river water at many mine sites fails these limits, so stations need a small treatment plant, often softening or reverse osmosis, dedicated to cooling make-up.

Never top up with untreated water during an emergency without recording it. A few hundred litres of hard water added to a circuit can lay down scale in cylinder heads and charge air coolers that later shows up as rising temperatures. Our guide to cylinder head reconditioning shows how scale and corrosion on the water side shorten head life.

Choosing and dosing the inhibitor

Most medium-speed engine makers approve a short list of inhibitor products, commonly nitrite-borate formulations or organic acid technology types. Only approved products should be used, and different types should not be mixed, because their protective films can interfere with each other.

Dosing is calculated from the system volume and the target concentration. For example, if the target nitrite level is 1,500 mg per litre and a 1,800 litre circuit tests at 1,000 mg per litre, the shortfall is 500 mg per litre, or about 0.9 kilograms of active nitrite for the whole circuit, which the product data sheet converts into a dose of concentrate. Dosing should be done slowly into circulating water, never as a single slug.

When glycol is needed

Glycol is rarely required for freezing protection on most African sites, but some high-altitude stations and stations with remote radiators exposed to cold nights do use it. Glycol reduces heat transfer slightly, so the cooling system must be designed for the mixture.

Where glycol is used, the inhibitor must be compatible with it and the glycol concentration becomes another parameter to test. Degraded glycol turns acidic and can attack metals quickly, so the pH reading becomes even more important.

What to test and how often

  • Inhibitor concentration: weekly with a field test kit.
  • pH: weekly, kept inside the maker’s band, usually mildly alkaline.
  • Chlorides and hardness: monthly, as signs of poor make-up or contamination.
  • Conductivity: monthly, as a general measure of dissolved salts.
  • Oil, fuel or exhaust gas traces: whenever the water looks discoloured or the header tank level moves unexpectedly.
  • Full laboratory analysis: quarterly, to confirm the field results.

Field kits are simple and cheap, so the service team on site can run them as part of a routine round. Results should be recorded per engine, not per station, because one engine with a slow leak or a failing seal can drift away from the others.

Make-up volume as an early warning

Fitting a water meter on the make-up line to each engine circuit is one of the most useful additions on an older station. A sudden rise in make-up volume points to a leak, a failing pump seal or water passing into the combustion space through a cracked head or liner seal.

Remote monitoring systems can log make-up volume and header tank level alongside jacket water temperatures. Our article on remote generator monitoring explains how such signals are collected from sites where engineers cannot be present every day.

Contamination from oil and exhaust gas

Oil in the cooling water usually comes from a leaking lube oil cooler or a failed seal, and it coats heat transfer surfaces. Exhaust gas in the water, often shown by bubbles in the header tank or rapidly falling pH, suggests a cracked head, a failed liner seal or a leaking exhaust gas cooler where one is fitted.

These faults should be found quickly, because the water chemistry cannot protect the engine while contamination continues. The fix is mechanical, followed by cleaning and refilling the circuit with fresh treated water.

Cleaning and flushing a neglected circuit

When an engine has run for a long time with poor water, scale and corrosion products build up in cooling passages. Chemical cleaning with an approved descaling agent, followed by neutralising, flushing and refilling with treated water, restores heat transfer and gives the inhibitor clean metal to protect.

This work is best done during a planned stop such as a major overhaul. Our overview of HFO engine overhaul planning shows how water-side cleaning fits into the overhaul scope.

Records and handover

A cooling water logbook for each engine, showing every test result, dose and top-up, is the single best record of how well an engine has been looked after. Buyers and insurers increasingly ask to see it, and engine makers may ask for it when assessing a warranty claim.

When a new O&M team takes over a station, the logbook, the approved product list and a stock of inhibitor and test reagents should be part of the handover. Running out of reagents is a common reason that testing quietly stops on remote sites. Engines coming back from rebuild and refurbishment work should also arrive with a clean, freshly treated circuit and a record of what was used.

About the authors

This guide comes from the USP&E service engineers and station chemists who test jacket water and dose inhibitors on the HFO engines we look after on African mine and utility stations. USP&E is an EPC and O&M contractor, not a broker, with 150+ power projects in 45+ countries, 25,000 MW contracted since 2002 and 24+ years in the field. Our station operation and maintenance service includes water treatment routines on every engine we run.

Offices: Colorado Springs (1755 Telstar Dr, Suite 300), Knoxville (800 S Gay St, Suite 700), London (162-168 Regent Street), Johannesburg (22 Kildoon Rd, Bryanston), Cape Town (31 Brickfield Road, Woodstock) and China (No. 1 Ningzhou Road, Wuxi). Regions: USA | AFRICA | UK | UAE | CHINA. ISO 9001 and ISO 45001 certified.

Cooling water treatment questions

Why does a closed engine cooling circuit need treatment?

Top-up water brings in oxygen and salts, and liner vibration causes cavitation. An inhibitor film and controlled water quality protect the metal.

What inhibitor is used in HFO engine jacket water?

Usually a nitrite-borate or organic acid type product approved by the engine maker. Different types should not be mixed.

How often should cooling water be tested?

Inhibitor level and pH weekly, chlorides, hardness and conductivity monthly, and a full laboratory analysis about every quarter.

Can borehole water be used to top up an engine?

Only after treatment to meet the maker’s limits on hardness, chlorides and pH, often by softening or reverse osmosis.

What does rising make-up volume mean?

It usually points to a leak, a failing pump seal or water entering the combustion space, and should be investigated quickly.

What causes bubbles in the header tank?

Often exhaust gas entering the water through a cracked cylinder head or failed liner seal, which needs mechanical repair.

Check your cooling water routine

Send recent test results and the engine models on your station, and our service team will review your water treatment routine and testing schedule.

Use the engine service request form for a structured request, email info@uspeglobal.com with any site data you hold, or ring +27 10 822 2324 to speak to an engineer. Replacement HFO engines and complete generating sets are listed in our equipment stock list.


Where we operate

USA | AFRICA | UK | UAE | CHINA

USP&E United States

Colorado Springs Office: 1755 Telstar Dr, Suite 300

Knoxville Office: 800 S Gay St, Suite 700

USP&E South Africa

Johannesburg Office: 22 Kildoon Rd, Bryanston

Cape Town Office: 31 Brickfield Road, Woodstock

USP&E United Kingdom

London Office: 162-168 Regent Street

USP&E China

China Office: No. 1, Ningzhou Road, Wuxi

Call:+27 10 822 2324  |  E:info@uspeglobal.com

ISO Certifications
ISO9001ISO45001

Powering Possibility. Built for the Frontier.
Full-service EPC & O&M. Not a broker.

© 2026 USP&E · Generator Service Africa is part of USP&E

Leave a Comment

Your email address will not be published. Required fields are marked *